SUN-120-125-130-135-136K-G01P3 -EU-AM8 Three Phase | 120-136Kw | 8 MPPT
Higher yields / Safe & Reliable / Smart / User-friendly
The Deye 120-136K grid-connected inverter is made especially for ground-mounted solar PV systems and medium- and large-scale commercial rooftops that value stability and dependability. A quicker return on investment is guaranteed by the complete series inverter's 30% DC input oversizing ratio and 10% AC output overloading ratio. In the event of an accident, Deye's full series inverters may be remotely shut down right away thanks to the smart monitoring platform. PV plant operation and maintenance are also made easier by remote parameter adjustment and firmware updates.





8 MPP trackers, Max. efficiency up to 98.8%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Type II DC/AC SPD
Anti-PID function(Optional)
Technical Specifications
| Model | SUN-120K-G01P3 -EU-AM8 |
SUN-125K-G01P3 -EU-AM8 |
SUN-130K-G01P3 -EU-AM8 |
SUN-135K-G01P3 -EU-AM8 |
SUN-136K-G01P3 -EU-AM8 |
|---|---|---|---|---|---|
| Input Side | |||||
| Max. DC Input Power (kW) | 180 | 187.5 | 195 | 202.5 | 204 |
| Max. DC Input Voltage (V) | 1100 | ||||
| Start-up DC Input Voltage (V) | 250 | ||||
| MPPT Operating Range (V) | 2001000 | ||||
| Max. DC Input Current (A) | 40+40+40+40+40+40+40+40 | ||||
| Max. Short Circuit Current (A) | 60+60+60+60+60+60+60+60 | ||||
| No.of MPP Trackers | 8 | ||||
| No.of Strings per MPP Tracker | 4+4+4+4+4+4+4+4 | ||||
| Output Side | |||||
| Rated Output Power (kW) | 120 | 125 | 130 | 135 | 136 |
| Max. Active Power (kW) | 132 | 135 | 135 | 135 | 136 |
| Rated Output Voltage/Range (V) | 3L/N/PE 220/380V, 230/400V, 0.85Un-1.1Un (this may vary with grid standards) | ||||
| Rated Grid Frequency (Hz) | 50/60 (Optional) | ||||
| Operating Phase | Three Phase | ||||
| Rated AC Grid Output Current (A) | 181.9/174 | 189.4/181.2 | 197/188.5 | 204.6/195.7 | 206.1/197.2 |
| Max. AC Output Current (A) | 200/191.4 | 204.6/195.7 | 204.6/195.7 | 204.6/195.7 | 206.1/197.2 |
| Output Power Factor | >0.99 | ||||
| Total Harmonics Current Distortion (THDi) | <3% | ||||
| DC Injection Current (mA) | <0.5% | ||||
| Grid Frequency Range | 45-55 or 55-65 (Optional) | ||||
| Efficiency | |||||
| Max. Efficiency | 98.8% | ||||
| Euro Efficiency | 98.3% | ||||
| MPPT Efficiency | >99% | ||||
| Protection | |||||
| DC Reverse Polarity Protection | Yes | ||||
| AC Short Circuit Protection | Yes | ||||
| AC Output Overcurrent Protection | Yes | ||||
| Output Overvoltage Protection | Yes | ||||
| Insulation Resistance Protection | Yes | ||||
| Ground Fault Monitoring | Yes | ||||
| Anti-islanding Protection | Yes | ||||
| Temperature Protection | Yes | ||||
| Integrated DC Switch | Yes | ||||
| Remote Software Upload | Yes | ||||
| Remote Change of Operating Parameters | Yes | ||||
| Surge protection | DC Type II / AC Type II | ||||
| General Data | |||||
| Size (mm) | 1006W × 516H × 325.5D (Excluding Connectors and Brackets) | ||||
| Weight (kg) | 103 | ||||
| Topology | Transformerless | ||||
| Internal Consumption | <1W (Night) | ||||
| Running Temperature | -25 to +60°C, >45°C Derating | ||||
| Ingress Protection | IP65 | ||||
| Noise Emission (Typical) | ≤65 dB | ||||
| Cooling Concept | Smart Cooling | ||||
| Permissible Altitude (m) | 4000 | ||||
| Designed Lifetime | 8 Years | ||||
| Grid Connection Standard | IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110 | ||||
| Operating Surroundings Humidity | 0-100% | ||||
| Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||
| Features | |||||
| Display | LCD 240 × 160 | ||||
| Interface | RS485/RS232/WiFi/LAN | ||||