SUN-3.6/4/4.2/5/5.2/6/6.2K-G03 Single Phase 3.6-6.2 Kw | 1 MPPT

Higher yields / Safe & Reliable / Smart / User-friendly

The single-phase inverter is one of the best options for residential application thanks to its smaller size and local LCD display, buttons. Also, with built-in zero-export function (external CT is needed), it offers true ease and comfort for PV system operators and installers.​

1
2
2
  • 1 MPPT tracker, Max. efficiency up to 97.5%
  • Zero export application,VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range
  • Anti-PID function(Optional)
  • Low start-up voltage of 80V

Technical Specifications

Model SUN-3.6K-G03 SUN-4K-G03 SUN-4.2K-G03 SUN-4.6K-G03 SUN-5K-G03 SUN-5.2K-G03 SUN-6K-G03 SUN-6.2K-G03
PV String Input Data
Max. PV Input Power (kW)4.75.25.566.56.87.88.1
Max. PV Input Voltage (V)600
Start-up Voltage (V)80
MPPT Voltage Range (V)70-550
Rated PV Input Voltage (V)360
Max. Operating PV Input Current (A)20
Max. Input Short Circuit Current (A)30
No. of MPPT Trackers/ No. of Strings per MPP Tracker1/2
AC Output Side
Rated AC Output Active Power (kW)3.644.24.655.266.2
Max. AC Output Apparent Power (kVA)3.964.44.625.065.55.726.66.82
Rated AC Output Current (A)16.4/15.718.2/17.419.1/18.321/2022.8/21.823.7/22.727.3/26.128.2/27
Max. AC Output Current (A)18/17.320/19.221/20.123/2225/2426/24.930/27.731/29.7
Rated Output Voltage/Range (V)220/230 0.85Un-1.1Un
Grid Connection FormL/N/PE
Rated Output Grid Frequency/Range (Hz)50/45-55, 60/55-65
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi<3%
DC Injection Current<0.5%In
Efficiency
Max. Efficiency97.3%97.5%
Euro Efficiency96.9%97.0%
MPPT Efficiency>99%
Equipment Protection
DC Polarity Reverse Connection ProtectionYes
AC Output Overcurrent ProtectionYes
AC Output Overvoltage ProtectionYes
AC Output Short Circuit ProtectionYes
Thermal ProtectionYes
DC Terminal Insulation Impedance MonitoringYes
DC Component MonitoringYes
Ground Fault Current MonitoringYes
Power Network MonitoringYes
Island Protection MonitoringYes
Earth Fault DetectionYes
Overvoltage Load Drop ProtectionYes
Residual Current (RCD) DetectionYes
Surge Protection LevelTYPE II (DC), TYPE II (AC)
Interface
Communication InterfaceRS485 / RS232 / WiFi / LAN
General Data
Operating Temperature Range (°C)-25 to +65°C, >45°C Derating
Permissible Ambient Humidity0-100%
Permissible Altitude (m)3000m
Noise (dB)≤35
Ingress Protection (IP) RatingIP65
Inverter TopologyNon-isolated
Over Voltage CategoryOVC II (DC), OVC III (AC)
Cabinet Size (W×H×D mm)305 × 280 × 180 (Excluding Connectors and Brackets)
Weight (kg)7.7
Warranty5 Years
Type of CoolingNatural Cooling
Grid RegulationIEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2