SUN-18/20/25K-G05 Three Phase | 18-25kW | 2 MPPT

Higher yields / Safe & Reliable / Smart / User-friendly

This new series of three-phase output inverter has wider range of 18kw, 20kw, 25kw than the original series, at the same time still go two integrated MPPTs, allowing two-array to input from different roof orientations. In addition, it allows the system to be monitored and controlled remotely.

1
2
  • 2 MPPT tracker, Max. efficiency up to 98.5%
  • Zero export application, VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range
  • Anti-PID function(Optional)

Technical Specifications

Model SUN-18K-G05 SUN-20K-G05 SUN-25K-G05
Input Side
Max. DC Input Power (kW)23.42632.5
Max. DC Input Voltage (V)1100
Start-up DC Input Voltage (V)250
MPPT Operating Range (V)200–1000
Max. DC Input Current (A)26+26
Max. Short Circuit Current (A)39+39
Number of MPPT2
Strings per MPPT2+2
Output Side
Rated Output Power (kW)182025
Max. Active Power (kW)19.82227.5
Rated Output Voltage/Range (V)3L/N/PE 220/380V, 230/400V, 0.85Un–1.1Un (this may vary with grid standards)
Rated Grid Frequency (Hz)50/60 (Optional)
Operating PhaseThree phase
Rated AC Grid Output Current (A)27.3/26.130.3/2937.9/36.2
Max. AC Output Current (A)30/28.733.3/31.941.7/39.8
Output Power Factor0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi)<3%
DC Injection Current (mA)<0.5%
Grid Frequency Range45–55 or 55–65 (Optional)
Efficiency
Max. Efficiency98.6%
Euro Efficiency97.83%
MPPT Efficiency>99.9%
Protection
DC Reverse-Polarity ProtectionYes
AC Short Circuit ProtectionYes
AC Output Overcurrent ProtectionYes
Insulation Resistance ProtectionYes
Ground Fault MonitoringYes
Anti Islanding ProtectionYes
Temperature ProtectionYes
Integrated DC SwitchYes
Remote (DC Switch)Yes
Remote software uploadYes
Remote change of operating parametersYes
Surge ProtectionDC Type II / AC Type II
General Data
Size (mm)362×527×220 (Excluding Connectors and Brackets)
Weight (kg)20
TopologyTransformerless
Internal Consumption<1W (Night)
Running Temperature-25 to +65βH, >45βH derating
Ingress ProtectionIP65
Noise Emission (Typical)≤40 dB
Cooling ConceptSmart cooling
Max. Operating Altitude Without Derating4000m
Designed Lifetime8 Years
Grid Connection Standard IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE217002, OVE-Richtlinie R25 , G99,VDE-AR-N 4105
Operating Surroundings Humidity0–100%
Safety EMC / Standard IEC/EN 61000-6-1/ 2/ 3/ 4, IEC/EN 62109-1; IEC/EN 62109-2
Features
DisplayLCD1602
InterfaceRS485/RS232/Wifi/LAN